Andersson, A. & Carlson, E-S. (2012). Structures in Underground Facilities. Analysis of a Concrete Column’s Capacity to Withstand Extraordinary Fire Loads. Studentrapport 2012:9 i serien Studies in Sustainable Technology vid Mälardalens högskola.
This report presents a Master of Science in Engineering work, carried out at Mälardalen’sUniversity within the research project METRO. The aim for this work was to determineif a concrete column placed close to the tracks at a subway station can withstand theeffect and temperature of a fire in a burning train comparable to the effects and temperaturesthat showed at the full scale test carried out within the METRO project. A literature review was made before a following case study. The results from thiswork show that the column is negligible affected by the fire.